    High Performance 3D PET Reconstruction Using Spherical Basis Functions on a Polar Grid

    Get PDF
    Statistical iterative methods are a widely used method of image reconstruction in emission tomography. Traditionally, the image space is modelled as a combination of cubic voxels as a matter of simplicity. After reconstruction, images are routinely filtered to reduce statistical noise at the cost of spatial resolution degradation. An alternative to produce lower noise during reconstruction is to model the image space with spherical basis functions. These basis functions overlap in space producing a significantly large number of non-zero elements in the system response matrix (SRM) to store, which additionally leads to long reconstruction times. These two problems are partly overcome by exploiting spherical symmetries, although computation time is still slower compared to non-overlapping basis functions. In this work, we have implemented the reconstruction algorithm using Graphical Processing Unit (GPU) technology for speed and a precomputed Monte-Carlo-calculated SRM for accuracy. The reconstruction time achieved using spherical basis functions on a GPU was 4.3 times faster than the Central Processing Unit (CPU) and 2.5 times faster than a CPU-multi-core parallel implementation using eight cores. Overwriting hazards are minimized by combining a random line of response ordering and constrained atomic writing. Small differences in image quality were observed between implementations

    Determination of total plasma hydroperoxides using a diphenyl-1- pyrenylphosphine fluorescent probe

    Get PDF
    Plasma hydroperoxides (HPs) are widely accepted to be good indicators of oxidative stress. By means of the method proposed here, which uses diphenyl-1-pyrenylphosphine (DPPP) as a fluorescent probe, all types of plasma HP were determined. The limits of detection and quantification of the method were 0.08 and 0.25 nmol of cumene hydroperoxide (CHP) equivalents in 40 Όl of plasma, respectively. The method is satisfactory in terms of precision (5.3% for 14.5 ΌM CHP eq., n = 8), and the recoveries were 91% and 92% after standard additions of 26 and 52 ΌM CHP, respectively. The selectivity of the proposed method is higher than 96%. Moreover, optimization of the reaction conditions and the addition of ethylenediaminetetraacetic acid (EDTA) disodium salt and 2,6-di-tert-butyl-4-methylphenol (BHT) prevented the formation of HP artifacts during the analysis. Therefore, the proposed method is useful for simple and quantitative determination of total plasma HPs. © 2012 Elsevier Inc. All rights reserved.Peer Reviewe

    Nucleon and delta masses in QCD

    Get PDF
    Using the positivity of the path integral measure of QCDQCD and defining a structure for the quark propagator in a background field according to the fluxon scenario for confinement, we calculate and compare the correlators for nucleon and delta. From their shape we elucidate about the origin of their mass difference, which in our simplified scenario is due to the tensor structure in the propagator. This term arises due to a dynamical mechanism which is responsible simultaneously for confinement and spontaneous chiral symmetry breaking. Finally we discuss, by comparing the calculated correlators with the Lehmann representation, the possibility that a strong CP and/or P violation occurs as a consequence of a specific mechanism for confinement.Comment: Latex, FTUV/92-2

    Evaluation of resistive-plate-chamber-based TOF-PET applied to in-beam particle therapy monitoring

    Get PDF
    Particle therapy is a highly conformal radiotherapy technique which reduces the dose deposited to the surrounding normal tissues. In order to fully exploit its advantages, treatment monitoring is necessary to minimize uncertainties related to the dose delivery. Up to now, the only clinically feasible technique for the monitoring of therapeutic irradiation with particle beams is Positron Emission Tomography (PET). In this work we have compared a Resistive Plate Chamber (RPC)-based PET scanner with a scintillation-crystal-based PET scanner for this application. In general, the main advantages of the RPC-PET system are its excellent timing resolution, low cost, and the possibility of building large area systems. We simulated a partial-ring scannerbeam monitoring, which has an intrinsically low positron yield compared to diagnostic PET. In addition, for in-beam PET there is a further data loss due to the partial ring configuration. In order to improve the performance of the RPC-based scanner, an improved version of the RPC detector (modifying the thickness of the gas and glass layers), providing a larger sensitivity, has been simulated and compared with an axially extended version of the crystal-based device. The improved version of the RPC shows better performance than the prototype, but the extended version of the crystal-based PET outperforms all other options. based on an RPC prototype under construction within the Fondazione per Adroterapia Oncologica (TERA). For comparison with the crystal-based PET scanner we have chosen the geometry of a commercially available PET scanner, the Philips Gemini TF. The coincidence time resolution used in the simulations takes into account the current achievable values as well as expected improvements of both technologies. Several scenarios (including patient data) have been simulated to evaluate the performance of different scanners. Initial results have shown that the low sensitivity of the RPC hampers its application to hadro

    Hadron Correlators and the Structure of the Quark Propagator

    Get PDF
    The structure of the quark propagator of QCDQCD in a confining background is not known. We make an Ansatz for it, as hinted by a particular mechanism for confinement, and analyze its implications in the meson and baryon correlators. We connect the various terms in the K\"allen-Lehmann representation of the quark propagator with appropriate combinations of hadron correlators, which may ultimately be calculated in lattice QCDQCD. Furthermore, using the positivity of the path integral measure for vector like theories, we reanalyze some mass inequalities in our formalism. A curiosity of the analysis is that, the exotic components of the propagator (axial and tensor), produce terms in the hadron correlators which, if not vanishing in the gauge field integration, lead to violations of fundamental symmetries. The non observation of these violations implies restrictions in the space-time structure of the contributing gauge field configurations. In this way, lattice QCDQCD can help us analyze the microscopic structure of the mechanisms for confinement.Comment: 12 pp in LaTeX, preprint Univ. of Valencia, FTUV/94-16, IFIC/94-15. To appear in Z.Phys.

    Effect of feeding olive pomace acid oil on dark chicken meat lipid composition, oxidative stability, color, and sensory acceptance

    Full text link
    This study evaluated the effect of using olive pomace acid oil (OPAO) instead of crude palm oil (PO) or refined olive pomace oil (ROPO) on lipid composition, lipid oxidation, and quality of chicken meat. Broiler chickens were fed diets with 6% of PO, ROPO, or OPAO, and deboned legs with skin were sampled. Fresh and refrigerated (commercial conditions; 7 days) chicken meat samples were assessed for fatty acid (FA) composition, tocopherol (T) and tocotrienol (T3) content, lipid oxidative stability, 2-thiobarbituric acid (TBA) values, volatile compounds, color, and sensory acceptance. Using ROPO and OPAO led to meat richer in monounsaturated FAs and OPAO to lower α-T levels compared to PO. Oxidative stability, TBA values, volatile compounds, and overall acceptance of meat were not affected by diet. Refrigeration increased TBA values and some volatile compounds’ concentrations, but it did not decrease redness or consumers’ overall acceptance. Therefore, the OPAO used was an adequate fat source for chicken diets at 6%, as it produced dark meat lower in saturated FAs than PO without affecting lipid oxidation or overall acceptance. According to this, upcycling OPAO as an energy source in chicken diets would be possible, which can contribute to the sustainability of the food chain. Keywords: edible oil refining by-product; upcycling; chicken feed; chicken diet; poultry meat quality; fat by-product; broiler meat; meat refrigeration; palm oil; olive pomace oi
    • 